Features
Universal AC input/Full range
Ac inlet:C14/C6/C8
Built-in Active PFC Function
No load power consumption<0.075W
Energy efficiency Level VI
Comply with EISA 2007/DOE,NRC,AU GEMS, EU ERP and COC version 5
Class Ⅰ or Class Ⅱ power
Protections:short circuit /Overload/Over Voltage/Over temperature
Fanless design with -10 to +40℃
Fully enclosed plastic case
LED indicator for power on.
Safer plastic insulation shell design
Product spec
Specification
O/P Voltage |
O/P Current |
Ripple & Noise(Max.) |
Voltage Accuracy |
Line Regulation |
Load Regulation |
O/P Power(max.) |
12.0 V |
0.1-6.67 A |
300 mVp-p |
±5% |
±1% |
±5% |
90W |
19.0 V |
0.1-4.73A |
350 mVp-p |
±5% |
±1% |
±5% |
90W |
24.0 V |
0.1-3.75A |
350 mVp-p |
±5% |
±1% |
±5% |
90W |
36.0 V |
0.1-2.5A |
350 mVp-p |
±5% |
±1% |
±5% |
90W |
48.0 V |
0.1-1.87A |
350 mVp-p |
±5% |
±1% |
±5% |
90W |
All Model List
Rated O/P voltage range (Vdc) |
Rated O/P Current range (A) |
Max. O/P power (W) |
12.0-20.0 |
0.10-6.67 | 90.08 |
20.1-30.0 |
0.10-4.47 |
90.00 |
30.1-54.00 |
0.10-2.99 | 90.00 |
Certificates and approvals
● CB, CE, GS, UL/CUL, FCC, SAA, RCM, CCC, PSE, KC, KCC
Safety standards
● IEC/EN 62368-1, UL/CUL 62368-1, GB 4943.1,J60950-1(H27), J62368-1(H30), AS/NZS 60950.1, AS/NZS 60065, K60950-1
EMC standards
● EMI standards: EN55032, FCC Part15 Subpart B, ANSI C63.4
● EMS standards:EN55024, EN55035, EN61000-3-2, EN61000-3-3